ID 110655

Tv factor P-AXIS-00765 for distance control is out of permissible range.

Description

The I-Tn derivative action time P-AXIS-00765 for distance control may not be outside the limit values.

Response

Class

1

Warning and correction of parameter. P-AXIS-00765 is automatically limited to maximum with values that are too large or to minimum if the values are too small.

Solution

Class

1

Check and modify P-AXIS-00765

Parameter

%1:

Logical axis number [-]

Logical axis number P-AXIS-00016 of concerned axis.

%2:

Error value [-]

Incorrect value of P-AXIS-00765

%3:

Lower limit value [-]

Lower limit value of P-AXIS-00765

%4:

Upper limit value [-]

Upper limit value of P-AXIS-00765

%5:

Corrected value [-]

Corrected value of P-AXIS-00765

Error type

2, Error message by data transfer from parameter list into control device.