Compatibility for measuring with #CS/Transformation (P-CHAN-00440)

P-CHAN-00440

Mode of measuring function with coordinate system / kinematics

Description

This parameter is used to influence the mode of operation of the measuring function in connection with active coordinate systems and / or kinematics.

 

Value 0:

When measuring with a coordinate system (e.g. #CS[]), the three ACS axes corresponding to the coordinate system axes must be parameterised as measuring axes. The measuring signal must be looped through so that all three main axes are latched during the measuring process and the CNC can calculate a PCS measuring point with consistent values in X, Y, Z in space.

When measuring with active kinematics (e.g. #TRAFO), the ACS axes affected by the kinematics must be parameterised as measuring axes. The measuring signal must be looped through so that all ACS axes of the kinematics are latched during the measuring process and the CNC can calculate a PCS measuring point X, Y, Z in space.

If no measured value is provided in one of the ACS measuring axes affected by the coordinate system or the kinematics, or if it was not parameterised as a measuring axis, the CNC generates a warning message that the PCS measuring position cannot be calculated.

 

Value 1:

Use the current ACS command value for ACS axes that are not measuring axes and do not move during the measurement run. The CNC can then calculate the correct PCS measuring point X, Y, Z in space.

If ACS measuring axes of the coordinate system or the kinematics move in the measuring block and no measured value is provided, the CNC generates a warning message. The PCS measuring position cannot be calculated.

Parameter

meas_trafo_with_cmd_pos

Data type

BOOLEAN

Data range

0 / 1

Dimension

----

Default value

0

Remarks

Available as of V2.2039.01