ID 70595
| Filter for function Improved Position Control could not be generated. | ||||
| Description | Several filters must be initialised for the Improved Position Control function. It was not possible to initialise a relevant filter. | |||
| Response | Class | 7 | Controlled halt of the axis, the control loop is closed.. The Improved Position Control function is disabled. | |
| Solution | Class | 6 | Check and correct the filter parameters | |
| Parameter | %1: | Logical axis number [-] | ||
| Logical axis number P-AXIS-00016 of axis affected. | ||||
| %2: | Instance [-] | |||
| Step where it was impossible to initialise the filter. | ||||
| %3: | Current value [-] | |||
| Further information why the filter could not be initialised. | ||||
| %4: | Error value [-] | |||
| Filter type could not be initialised. | ||||
| %5: | Status [-] | |||
| The Improved Position Control function is disabled by P-AXIS-00758. | ||||
| Error type | 11, Error message from position controller. | |||
| 
 | ||||