Machine natural frequency (P-AXIS-00589)
| P-AXIS-00589 | Machine natural frequency | |
| Description | This parameter specifies the machine’s natural frequency which the Vibration Guard function is to suppress. | |
| Parameter | vib_guard.freq | |
| Data type | REAL64 | |
| Data range | 1 ≤ freq | |
| Axis types | T, R, S | |
| Dimension | T: Hz | R,S: Hz | 
| Default value | 30 | |
| Drive types | ---- | |
| Remarks | The parameter is available as of V3.1.3075.00 | |