FIR filters - activation (P-AXIS-00573)

P-AXIS-00573

Enable axis-specific FIR filter

Description

This parameter controls the general enabling/disabling of the filter function.

Parameter

filter_fir.enable

Data type

BOOLEAN

Data range

0: Filter is disabled

1: Filter is enabled

Axis types

T, R, S

Dimension

T: ----

R,S: ----

Default value

0

Drive types

----

Remarks

The filter function is only activated if a valid filter type is selected (P-AXIS-00586), otherwise the filter is inactive.

Alternatively, the filter can also be enabled or disabled with the NC command #FILTER ON/OFF.

The parameter is available as of V3.1.3075.00