ID110632
| Invalid value for filter share factor. | ||||
| Description | The filter share factor (P-AXIS-00590) was configured with an invalid value. The value value range is from 0 to 100%. With a configured value less than 0, the value is corrected to 0 so that the filter is deactivated. | |||
| Response | Class | 1 | The filter share factor P-AXIS-00590 is corrected and the start-up is continued. | |
| Solution | Class | 1 | Check and modify the parameters. | |
| Parameter | %1: | Logical axis number [-] | ||
| Logical axis number of the axis where the invalid combination was configured. | ||||
| %2: | Error value[%] | |||
| Incorrectly parameterised filter share factor P-AXIS-00590 | ||||
| %3 | Corrected value [%] | |||
| Corrected filter share factor | ||||
| Error type | 2, Error message by data transfer from parameter list into control device. | |||
| 
 | ||||