Parameters

In addition to the parameters described, the SysCalibConfigLaser.nc calibration file is executed during the cycle. Its function is to parameterise the laser measuring station and must be filled with the result values of the calibration cycle.

Required input parameters

Input parameters

Description

@P65

type

0: length measurement

1: radius measurement

2: length and radius measurement

@P66

Measurement offset in Z for lateral measurements [mm, inch]

Only positive values are permissible.

Optional input parameters

Input parameters

Description

@P13

Clearance for lateral measurements [mm, inch]

Default value = current tool diameter (V.G.WZ_AKT.R*2)

@P23

Precision measurement repetitions

Default value = 1

@P33

Crossover range during measurement process [mm, inch]

Additional motion path that exceeds the expected contact point

Default value = current tool diameter (V.G.WZ_AKT.R)

@P37

Permissible tolerance of measuring point scatter.

Default value = 1/100 current tool diameter (0.01V.G.WZ_AKT.R)

If the difference of the measured values exceeds this tolerance, an error is output.

@P67

Lateral offset for length measurements [mm, inch]

Only positive values are permissible.

The value should stand at 0 for pointed tools, small tools and spherical tools.

Default value = 0

It is recommended to use the Syntax check to verify whether the input parameters are correctly assigned.