Parameters
In addition to the parameters described, the SysCalibConfigLaser.nc calibration file is executed during the cycle. Its function is to parameterise the laser measuring station and must be filled with the result values of the calibration cycle.
Input parameters | Description |
@P33 | Permissible tolerance of the measuring points to determine tool breakage. If this value is exceed, it is evaluated as a tool breakage. (default = 0.5) |
@P37 | Permissible tolerance of the measuring points to determine tool wear. (default = 0.1) It the tolerance is too small, it may result in unnecessary machine stops. |
@P67 | Radius offset (lateral offset when probing) Only positive values are permissible. Set the offset according to the tool measurement. (default = 0) |
@P70 | 0 (default) = warning when tool is worn, 1 = stop when tool is worn |
@P71 | 0 (default) = warning when tool breaks, 1 = stop when tool breaks |
It is recommended using the Syntax check to verify whether the input parameters have been correctly assigned.