Parameters
The touch probe must be configured in addition to supplying the input parameters described here. For more information on this function, see the section Configuration file.
The (calibrated) parameters of the touch probe (radius, length and offset in X and Y directions) are specified via the tool parameters.
Required input parameters
Input parameters | Description |
@P4 | Measurement path in the X axis (incremental) Positive value, the touch probe moves in positive X direction Negative value, the touch probe moves in negative X direction |
@P18 | Preposition along the Y axis before the 2nd measurement (incremental) @P18 may not be 0. |
Optional input parameters
Input parameters | Description |
@P7 | Zero offset to be described (TCS) G159=1 to G159=9 and G54 to G59 Input without address "G159=" or "G" If not specified, then measurement only but no write function Only permitted when G53 is active at cycle call. |
@P12 | Reference angle [degrees] Default value = 0 |
@P17 | Preposition along the X axis before the 2nd measurement [mm, inch] (incremental) Default value = 0 |
@P19 | Clearance length along the Z axis between the measurements (incremental) Default value = 0 |
@P22 | Preposition along the Z axis before the first measurement (incremental) If @P19 is not specified, the tool is retracted between the measurements by the value of @P22 Default value = 0 |
It is recommended to use the Syntax check to verify whether the input parameters are correctly assigned.