ID 150059

Illegal activation modifier within jog mode.

Description

An external application requests the CNC to activate the incremental jog manual operation mode for an axis. Therefore, the application commands an index of a parameter data set during activation, which contains values for jog velocity and jog step size.

 

The CNC detects that the axis parameter data set does not contain a parameter data set for incremental jog mode operation with this index.

Response

Class

1

Warning

The manual mode parameters are not transferred to the CNC. Axis couldn't be moved in manual operation mode.

Solution

Class

1

Please note that only a limited number of parameter data sets can be stored in the axis parameter data set for incremental jog mode.

If the incorrect index still lies within this limit, an additional parameter data set with the corresponding index can be created. Otherwise, we must use an index that already exists.

Parameter

%1:

Current value [-]

Value of the index for which there is no parameter data set for the incremental jog mode in the axis parameter data set.

Error type

-