ID 120627
| Rapid mode acceleration is greater than maximum value. | ||||
| Description | Rapid mode acceleration can be weighted with the function G231. Weighting is possible up to the maximum value a_max. Greater values are limited automatically. | |||
| Response | Class | 1 | Warning. | |
| Solution | Class | 1 | Reduce weighting value. | |
| Parameter | %1: | Logical axis number [-] | ||
| Logical axis number P-AXIS-00016 of axis affected. | ||||
| %2: | Current value [mm/s² or °/s²] | |||
| Weighted rapid mode acceleration value. | ||||
| %3: | Limit value [mm/s² or °/s²] | |||
| Maximum axis acceleration P-AXIS-00008. | ||||
| Error type | 2, Error message by data transfer from parameter list into control device. | |||
| 
 | ||||