ID 110608

The process data for the 'value_latched' signal was not found in the cyclic process data.

Description

When configuring the SERCOS real-time status bits for the signal 'measuring probe ½', the process data element configured in P-AXIS-00677 (probe 1) or P-AXIS-00683 (probe 2) was not found in the configured cyclic process data.

Response

Class

1

An error message is output containing the axis parameters P-AXIS-00118 (measurement axis) and P-AXIS-00098 (kasto_achse) are reset in order to prevent the execution of measurement run or edge banding with incompletely configured probes.

Solution

Class

1

Correct P-AXIS-00677/or P-AXIS-00683.

Parameter

%1:

Logical axis number [-]

Log. Axis number

%2:

Incorrect value [-]

Incorrect value of P-AXIS-00677/or P-AXIS-00683

%3:

Lower limit value [-]

Drive type

%4:

Upper limit value [-]

 

Error type

2, Error message by data transfer from parameter list into control device.