ID 110594
| Invalid bit number for additional 'Ready for Power test'. | |||||
| Description | Additional 'Ready for Power' test was enabled but the bit number configured in P-AXIS-00709 for this test is invalid. 
 The smallest permissible value for P-AXIS-00709 is 0. Depending on the length of the configured telegram element used to transfer the additional ready for power test information, the maximum value of this parameter is: | ||||
| Telegram element length | Maximum value for P-AXIS- 00709 | ||||
| 2 | 15 | ||||
| 4 | 31 | ||||
| This error message is also output if no value is configured for P-AXIS-00709. | |||||
| Response | Class | 3 | Error message output, ready for power test is disabled. | ||
| Solution | Class | 1 | P-AXIS-00709 must have a permissible value assigned, or disable the ‘Ready for Power' test. | ||
| Parameter | %1: | Logical axis number [-] | |||
| 
 | |||||
| %2: | Incorrect value [-] | ||||
| Current value of P-AXIS-00709. | |||||
| %3: | Limit value [-] | ||||
| Limit value for P-AXIS-00709. | |||||
| %4: | Corrected value [-] | ||||
| Corrected value of P-AXIS-00709. | |||||
| Error type | 2, Error message on data transfer of parameter lists to controller. | ||||
| 
 | |||||