ID 110512
| Homing on encoder overflow and homing on zero pulse can not be active at the same time. | ||||
| Description | Homing to encoder overflow (see P-AXIS-00294) and homing to zero pulse search (see P-AXIS-00386) have been activated simultaneously. | |||
| Response | Class | 1 | Error message output, reference to encoder overflow (P-AXIS-00294) is disabled. | |
| Solution | Class | 1 | Set either P-AXIS-00294 or P-AXIS-00386 to zero (nil). | |
| Parameter | %1: | Logical axis number [-] | ||
| Log. Axis number (see also P-AXIS-00016). | ||||
| %2: | Current value [-] | |||
| Value of P-AXIS-00386. | ||||
| %3: | Current value [-] | |||
| Value of P-AXIS-00294. | ||||
| %4: | Corrected value [-] | |||
| Corrected value of P-AXIS-00294. | ||||
| Error type | 2, Error message by data transfer from parameter list into control device. | |||
| 
 | ||||