ID 110511
| Only spindles can be operated without position control. | ||||
| Description | One axis is to be operated without position controller (controlled operation). This is only possible for spindles. See also P-AXIS-00320.. | |||
| Response | Class | 1 | Error message output, reset is locked. | |
| Solution | Class | 1 | Parameterise a different operation mode for the axis (see P-AXIS-00320) and restart the controller. | |
| Parameter | %1: | Logical axis number [-] | ||
| Log. axis number of the axis (see also P-AXIS-00016). | ||||
| %2: | Drive type [-] | |||
| Drive type of the axis (see also P-AXIS-00020). | ||||
| %3: | Incorrect value [-] | |||
| Operation mode configured for the axis (see also P-AXIS-00320). | ||||
| %4: | Current value [-] | |||
| Configured axis type (see P-AXIS-00018) | ||||
| %5: | Corrected value [-] | |||
| Corrected operation mode. | ||||
| Error type | 2, Error message on data transfer of parameter lists to controller. | |||
| 
 | ||||