ID 110508
| Probing is not supported for this transformation. | ||||
| Description | The axis is configured as probing axis (see P-AXIS-00118) and, at same time, an axis-specific feedback value transformation is configured for the axis that does not support probing. | |||
| Response | Class | 3 | Error message output; probing is disabled. | |
| Solution | Class | 7 | P-AXIS-00118 must be disabled. | |
| Parameter | %1: | Logical axis number [-] | ||
| Logical axis number P-AXIS-00016 of axis | ||||
| %2: | Current value [-] | |||
| Transformation if P-AXIS-00381 of the configured current value transformation. | ||||
| %3: | Incorrect value [-] | |||
| Value of P-AXIS-00118. | ||||
| %4: | Corrected value [-] | |||
| Corrected value of P-AXIS-00118. | ||||
| Error type | 2, Error message on data transfer of parameter lists to controller. | |||
| 
 | ||||