ID 110364
| Maximum distance is smaller than minimum distance during homing to fixed stop. | ||||
| Description | The value for kenngr.homing.torq_max_distance (P-AXIS-00345) may not be smaller than the value for kenngr.homing.torq_min_distance (P-AXIS-00344). | |||
| Response | Class | 1 | Warning, no reaction. | |
| Solution | Class | 1 | Check and modify the entered values for P-AXIS-00345 and P-AXIS-00344. | |
| Parameter | %1: | Logical axis number [-] | ||
| Logical axis number P-AXIS-00016 of concerned axis. | ||||
| %2: | Current value [0.1 10^-3 mm or ø] | |||
| Parameterised value of kenngr.homing.torq_max_distance (P-AXIS-00345). | ||||
| %3: | Current value [0.1 10^-3 mm or ø] | |||
| Parameterised value of kenngr.homing.torq_min_distance (P-AXIS-00344). | ||||
| Error type | 2, Error message by data transfer from parameter list into control device. | |||
| 
 | ||||