ID 110218
| Illegal grating of correction value intervals. | ||||
| Description | The step size between 2 interpolation points from the list of compensation values for leadscrew error compensation is specified in parameter P-COMP-00018. 
 The message is displayed because the value for the interval is < 0. | |||
| Response | Class | 3 | Correction of the value | |
| Solution | Class | 7 | Check and modify the parameter P-COMP-00018.  | |
| Parameter | %1: | Logical axis number [-] | ||
| Logical axis number P-AXIS-00016 of concerned axis | ||||
| %2: | Error value [Incr.] | |||
| The CNC uses this value for parameter P-COMP-00009 instead of the value indicated by the user. | ||||
| %3: | Lower limit value [Incr.] | |||
| 
 | ||||
| Error type | 2, Error message by data transfer from parameter list into control device. | |||
| 
 | ||||