ID 110141
| Incremental feed rate is greater than the maximum permissible feed rate. | ||||
| Description | With manual mode in “continuous jog mode”, the parameter P-AXIS-00077 defines the continuous jog velocity. The specified value is greater than the permissible maximum value and is limited to this value. | |||
| Response | Class | 1 | Warning and correction of parameter. | |
| Solution | Class | 1 | Check and correct the parameter P-AXIS-00077 | |
| Parameter | %1: | Logical axis number | ||
| Logical axis number P-AXIS-00016 of concerned axis. | ||||
| %2: | Current value [1µm/s or 0.001°/s] | |||
| Current velocity P-AXIS-00077. | ||||
| %3: | Upper limit value [1µm/s or 0.001°/s] | |||
| Maximum permissible velocity. | ||||
| %4: | Corrected value [1µm/s or 0.001°/s] | |||
| Corrected velocity P-AXIS-00077. | ||||
| %5: | Current value [-] | |||
| Array index of the incorrect entry | ||||
| Error type | 2, Error message by data transfer from parameter list into control device. | |||
| [1µm/s or 0.001°/s] | ||||