ID 110133

Percentage for interpolation feed rate in manual mode too small.

Description

In manual operation mode with parallel interpolation (G201), the axis dynamic values are distributed with percentage value between path interpolation and axis specific manual mode interpolator. The percentage of the maximum velocity P-AXIS-00212 for the path interpolator is determined by P-AXIS-00095.

The percentage of the maximum speed is set to the minimum value.

Response

Class

1

None.

Solution

Class

1

Set percentage share for manual operation mode P-AXIS-00095 greater than minimum value.

Parameter

%1:

Logical axis number [-]

Logical axis number P-AXIS-00016 of concerned axis.

%2:

Current value [0,1%]

Current percentage share value P-AXIS-00095.

%3:

Lower limit value [0,1%]

Lower limit value for percentage share value.

%4:

Corrected value [0,1%]

Corrected percentage share P-AXIS-00095.

Error type

2, Error message by data transfer from parameter list into control device.