ID 110126
| Maximum velocity for manual mode exceeds limit. | ||||
| Description | The maximum velocity P-AXIS-00213 in active manual mode is greater than the maximum value. The maximum velocity is set to default value. | |||
| Response | Class | 1 | None. | |
| Solution | Class | 1 | Set maximum velocity for manual mode P-AXIS-00213 to smaller than maximum value P-AXIS-00212. | |
| Parameter | %1: | Logical axis number [-] | ||
| Logical axis number P-AXIS-00016 of axis affected. | ||||
| %2: | Current value [1µm/s or 0.001°/s] | |||
| Current maximum velocity P-AXIS-00213. | ||||
| %3: | Limit value [1µm/s or 0.001°/s] | |||
| Upper limit value of velocity. | ||||
| %4: | Corrected value [1µm/s or 0.001°/s] | |||
| Corrected maximum velocity P-AXIS-00213. | ||||
| Error type | 2, Error message on data transfer of parameter lists to controller. | |||
| 
 | ||||