ID 110042
| D/A converter resolution is illegal (numerator). | ||||
| Description | The resolution of the drive command value is specified by numerator and denominator. Damping value = P-AXIS-00129 / P-AXIS-00128 An invalid value was specified for the numerator. | |||
| Response | Class | 1 | Warning and correction of parameter. | |
| Solution | Class | 1 | Check and modify P-AXIS-00129 in the parameter list of the affected axis. | |
| Parameter | %1: | Logical axis number [-] | ||
| Logical axis number P-AXIS-00016 of concerned axis | ||||
| %2: | Error value [-] | |||
| Configured value of P-AXIS-00129 | ||||
| %3: | Corrected value [-] | |||
| Error type | 2, Error message by data transfer from parameter list into control device. | |||
| 
 | ||||