ID 110042

D/A converter resolution is illegal (numerator).

Description

The resolution of the drive command value is specified by numerator and denominator.

Damping value = P-AXIS-00129 / P-AXIS-00128

An invalid value was specified for the numerator.

Response

Class

1

Warning and correction of parameter.

Solution

Class

1

Check and modify P-AXIS-00129 in the parameter list of the affected axis.

Parameter

%1:

Logical axis number [-]

Logical axis number P-AXIS-00016 of concerned axis

%2:

Error value [-]

Configured value of P-AXIS-00129

%3:

Corrected value [-]

P-AXIS-00129

Error type

2, Error message by data transfer from parameter list into control device.