ID 90178
| Illegal combination of parameters in multipath configuration. | |||
| Description | The parameters for using single or multi path configurations are incorrect in the start-up list and the channel parameter list. 
 In the channel parameter list the parameter multi_path_configuration 0 # Enable 2-path programming (P-CHAN-00261) is incorrectly set for the use of multipath configurations. 
 Correct setting for multipath configuration: Channel parameter list: multi_path_configuration 1 # Enable 2-path programming (P-CHAN-00261) Activate the function: configuration.tool_radius_comp.function MULTI_PATH # P-CHAN-00550 Alternatively, the function can be activated in the start-up list: configuration.channel[0].tool_radius_comp.function MULTI_PATH # P-STUP-00080 
 Correct setting for single path configuration (default): Delete both parameters in each of the lists. | ||
| Response | Class | 2 | Abort NC program processing. | 
| Solution | Class | 6 | Correct the parameters concerned in the channel parameter list (or start-up list.) | 
| Error type | 1, Error message from NC program. | ||
| 
 | |||