ID 90119

The programmed contour is not closed.

Description

When using the command inner corner selection of TRC, the following contour must be closed.

 

Closed contour means that the endpoint of block of selection must be identical with the endpoint of the last programmed point before deselection of TRC.

 

Single blocks and contours with only two motion blocks could not be selected with this method.

Response

Class

2

Abort NC program processing.

Solution

Class

6

Check and modify the first and the last motion while TRC is active.

Change to different TRC selection method for individual blocks or for contours with only two motion blocks.

Parameter

%1:

Error value [0.1 µm or 0.0001°]

Distance of the endpoint of block of selection to the endpoint of the last motion block before deselection of TRC.

%2:

Upper limit value [0.1 µm or 0.0001°]

Upper limit of distance.

Error type