ID 80044
Attenuation greater or equal to 1.  | ||||
Description  | The specified attenuation value for the simulation drive (P-AXIS-00020=4) is invalid. It must be smaller than one. Enter the attenuation value as a quotient of the parameters P-AXIS-00050 and P-AXIS-00051 in the axis parameter list.  | |||
Response  | Class  | 1  | Warning, reduce attenuation value to maximum permissible value.  | |
Solution  | Class  | 1  | Correct attenuation in the axis parameter  | |
Parameter  | %1:  | Logical axis number [-]  | ||
Logical axis number of affected axis, see P-AXIS-00016  | ||||
%2:  | Current value [-]  | |||
Specified attenuation value, see P-AXIS-00050, P-AXIS-00051  | ||||
%3:  | Limit value [-]  | |||
Maximum permissible attenuation value  | ||||
%4:  | Corrected value [-]  | |||
Corrected attenuation value  | ||||
Error type  | -  | |||
  | ||||