ID 70404
| Configured bitmask contains bits that are used also by the CNC. | ||||
| Description | The bitmask configured in P-AXIS-00429 for bitwise writing of drive values contains bits which are also used by the CNC. | |||
| Response | Class | 7 | Error message output, evaluation of drive functions is aborted. | |
| Solution | Class | 6 | Adjust P-AXIS-00429. | |
| Parameter | %1: | Logical axis number [-] | ||
| 
 | ||||
| %2: | Current value [-] | |||
| Name of the configured drive function (P-AXIS-00396). | ||||
| %3: | Current value [-] | |||
| Configured value of P-AXIS-00429 | ||||
| %4: | Current value [-] | |||
| Configured data type (P-AXIS-00399). | ||||
| %5: | Error value [-] | |||
| Permissible maximum value of P-AXIS-00429 | ||||
| Error type | 11, Error message from position controller. | |||
| 
 | ||||