ID 70380
| Maximum permissible path exceeded for zero pulse search or encoder overflow search. | ||||
| Description | During homing, the maximum permissible path set in parameter P-AXIS-00404 for searching the zero pulse or the encoder overflow was exceeded. Possible reasons for this error message are: 
 | |||
| Response | Class | 7 | Stop of axis, output of error message. | |
| Solution | Class | 6 | Possible solutions: 
 | |
| Parameter | %1: | Logical axis number [-] | ||
| Axis number (P-AXIS-00016). | ||||
| %2: | Current value [-] | |||
| Maximum permissible path during zero pulse search (value of P-AXIS-00404) | ||||
| %3: | Limit value [-] | |||
| Covered distance since start of zero pulse search. | ||||
| %4: | Current value [-] | |||
| Current actual axis position in increments. | ||||
| %5: | Current value [-] | |||
| Axis position at start of zero pulse search in increments. | ||||
| Error type | 1, Error message from NC program. | |||
| 
 | ||||