ID 70375

Inconsistent data for spindle revolution monitoring

Description

Data for spindle tool revolution monitoring is inconsistent.

With spindle tool revolution monitoring, limit speed and activation are stored in inverted and non-inverted.

To compare the two values, the second (inverted value) is inverted again and then compared with the first value. If these two values differ this error message is output.

Possible reasons for this error message are:

  • Configuration error, data was entered uncorrectly in the configuration data.
  • Error in data transmission.

Response

Class

5

Error message output, immediate stop of axis

Solution

Class

6

In case of an configuration error the data has to be corrected and the control restarted.

In case of an transmission error the control has to be reset.

Parameter

%1:

Logical axis number [-]

Log. Axis number (see P-AXIS-00016).

%2:

Current value [1µm/s or 0.001°/s]

First value.

%3:

 

Second (inverted) value, inverted again, must result to same value as Kennung_2.

%4:

 

First value inverted, must result in same value as Kennung_5.

%5:

 

Second (inverted) value.

Error type

11, Error message from position controller.