ID 70204
| Reset is locked since maximum permissible master/slave path distance was previously exceeded. | ||||
| Description | A controller reset is not possible because the maximum permissible path difference (see P-AXIS-00071) between the master and slave axis was exceeded previously in gantry mode. Resetting the control cannot solve this error. | |||
| Response | Class | 5 | 
 | |
| Solution | Class | 6 | Restart the controller | |
| Parameter | %1: | Current value [1µm/s or 0.001°/s] | ||
| Current path difference between master and slave | ||||
| %2: | Limit value [1µm/s or 0.001°/s] | |||
| Maximum permissible path difference, see P-AXIS-00071 | ||||
| %3: | Logical axis number [-] | |||
| Logical axis number of the slave axis, see P-AXIS-00016 | ||||
| %4: | Current value [1µm/s or 0.001°/s] | |||
| Current position of the slave axis | ||||
| %5: | Current value [1µm/s or 0.001°/s] | |||
| Current position of the master axis | ||||
| Error type | - | |||
| 
 | ||||