ID 60230
| Ramp time acceleration down-gradation is out of limits. | ||||
| Description | The ramp time for the acceleration down-gradation of the non-linear slope (jerk limited) according to the parameter P-AXIS-00195 was commanded smaller than the minimum value. The ramp time is corrected to minimum value. | |||
| Response | Class | 1 | None. | |
| Solution | Class | 1 | Command ramp time greater than minimum value. | |
| Parameter | %1: | 
 | ||
| Logical axis number P-AXIS-00016 of concerned axis. | ||||
| %2: | Current value [mm/s² or °/s²] | |||
| Commanded ramp time. | ||||
| %3: | Lower limit value [mm/s² or °/s²] | |||
| Minimum ramp time value. | ||||
| %4: | Corrected value [µs] | |||
| Corrected ramp time. | ||||
| Error type | 1, Error message from NC program.. | |||
| 
 | ||||