ID 60188

Acceleration ramp 1 is below limit.

Description

A movement was commissioned in which the acceleration level 1 is less than 1 mm/s2. The acceleration level 1 value is automatically corrected to 1 mm/s2.

The cause for this warning is indicated by the parameters 4 and 5 of this warning:

If parameter 4 equals 1, the movement was commissioned by the PLC and the invalid value was transferred during the commissioning.

Otherwise either P-AXIS-00011 or P-AXIS-00005 are less than 1 mm/s2.

Parameter 5 indicates which of the two values is incorrect.

Response

Class

1

Warning output, value is corrected to 1 mm/s2.

Solution

Class

1

Change erroneous value in axis parameter list or when commanding via HLI.

Parameter

%1:

 

Logical axis number (P-AXIS-00016) of the spindle

%2:

Current value [mm/s^2 bzw. °/s^2]

Current value.

%3:

Corrected value [mm/s^2 bzw. °/s^2]

Corrected value

%4:

Current value[-]

This value indicates if the erroneous value is passed over via the HLI.

1: The value was transferred via the HLI when the order was placed.

0: The invalid value comes from a parameter list. Parameter 5 of the error message indicates the erroneous value.

%5:

Current value[-]

If parameter 4 is zero (nil), this value indicates which parameter triggered the warning:

0: P-AXIS-00011 is faulty.

1: P-AXIS-00005 is faulty.

Error type

1, Error message from NC program.