ID 50609

End of motion range in direction of positive software limit switch reached.

Description

The positive motion range limit of the X axis was reached.

With throughfeed machining, the X axis co-moving with the conveyor decelerates in order to stop in front of the positive software limit switch. The error may only occur when the conveyor moving direction is positive.

 

There are different possible reasons:

  • The conveyor velocity is too high.
  • The feed rates in the NC program are too small.
  • Too many contour elements, or description is too extensive (path of Y axis)

Response

Class

4

Movement stop.

Solution

Class

6

Check and correct conveyor velocity and NC program

Parameter

%1:

Logical axis number [-]

Logical axis number (P-AXIS-00016) of affected axis

%2:

Limit value [0.1 µm or 0.0001°]

Positive limit of travel

%3:

Current value [0.1 µm or 0.0001°]

Current position including braking distance

%4:

Current value [0.1 µm or 0.0001°]

PCS 0 position

%5:

Current value [0.1 µm or 0.0001°]

Braking distance

Error type

1, Error message from NC program.