ID 50597
| Belt speed Conveyor velocity [CONV_VEL] for #SYNC IN not programmed or equal to 0. | ||||
| Description | In the first #SYNC IN command the velocity of the conveyor belt has to be specified | |||
| Response | Class | 4 | 
 | |
| Solution | Class | 6 | 
 | |
| Parameter | %1: | Current value [1µm/s or 0.001°/s] | ||
| 
 | ||||
| %2: | Lower limit value [1µm/s or 0.001°/s] | |||
| 
 | ||||
| Error type | 1, Error message from NC program. | |||
| 
 | ||||