ID 21424

Channel parameters: Invalid parameter setting of edge bending.

Description

When checking the edge bending parameters during ramp-up, the system determines that it only makes sense to set P-CHAN-00029 to 1 if P-CHAN-00149 and P-CHAN-00153 are set to 0.

Response

Class

1

Start-up of the control is continued.

Solution

Class

1

In the event of a conflict, the cross-motion edge bending P-CHAN-00029 is assigned 0 (FALSE) during the start-up and the start-up is continued.

Before the next start-up, set the channel parameters P-CHAN-00029, P-CHAN-00149 and P-CHAN-00153 correctly:

P-CHAN-00029

P-CHAN-00149

P-CHAN-00153

Check result

0

1

0

OK

0

0

1

OK

0

1

1

OK

1

0

0

OK

1

1

0

NOT OK

1

0

1

NOT OK

1

1

1

NOT OK

Parameter

%1:

Error value [-]

Channel parameter P-CHAN-00029 incorrectly assigned

%2:

Corrected value [-]

 

Error type

2, Error message by data transfer from parameter list into control device.