Channel parameters: Incorrect setting of number of groups.

Description

During start-up, the channel parameter check determines that the actual number of configured axis groups does not correspond to the specified total number of axis groups P-CHAN-00023.

Response

Class

1

Controller start-up is continued.

Solution

Class

1

During start-up in case of conflict the total number of axes groups is set to the smaller number of both values and the start-up is continued.

Note:

The complete number of configured axis groups in the channel parameter list may then not be available in the channel after start-up!

At the moment only one axis group (index 0) is permissible in the NC channel.

Parameter

%1:

Current value [-]

Real number of configured axes groups

%2:

Expected value [-]

Total number of axis groups P-CHAN-00023

%3:

Corrected value [-]

Total number of axis groups automatically corrected

Error type

2, Error message by data transfer from parameter list into control device.