ID 20124
| Double programmed path preparation commands. | ||||
| Description | In the same NC block, more than one G function was programmed from the look-ahead function group (G115/G116/G117). Example: Wrong: N10 G00 X0 Y0 Z0 N20 G115=2 G116 X1 : 
 | |||
| Response | Class | 2 | Abort NC program processing. | |
| Solution | Class | 3 | Check and modify NC program. Remove the inadmissible G function. | |
| Parameter | %1: | Error value [-] | ||
| Number of the incorrectly programmed G function | ||||
| Error type | 1, Error message from NC program. | |||
| 
 | ||||