ID 20118

Double-programmed unit declarations.

Description

In the same NC block, more than one G function has been programmed from the group of measure units (G70/G71).

Example:

Wrong:

N10   G00 X0 Y0 Z0

N20   G70 X100 G71

:

N1000 M30

Response

Class

2

Abort NC program processing.

Solution

Class

3

Check and modify NC program. Remove the inadmissible G function.

Parameter

%1:

Error value [-]

Number of the inadmissible programmed G function

Error type

1, Error message from NC program.