ID 13109

Unknown process defined.

Description

Various processes are available for drilling. They are selected by specifying an identification number:

0: With one cut (only available for thread tapping! (default)),

1: Step drilling with chip breaking,

2: Step drilling with chip evacuation.

 

This message is generated when an identification number other than 0, 1 or 2 was programmed in the corresponding data input parameters.

Response

Class

-

Error: Transition to error state. Complete reset of the NC channel necessary.

Solution

Class

-

Check and define the identification number of the process and correct the input parameters.

Error type

1, Error message from the NC program