Diameter display (P-CHAN-00256)

P-CHAN-00256

Diameter display during turning

Description

This parameter switches over the display of the (PCS) position values provided by the PLC interface (HLI) for turn machining. When the parameter is set to 1, the display shows the average value when diameter programming (G51) is active.

Parameter

display_diameter_pos

Data type

BOOLEAN

Data range

0: Radius display with active G51 (default).

1: Diameter display with active G51.

Dimension

----

Default value

0

Remarks