Including ball radius in PCS measurement value (P-CHAN-00311)
| P-CHAN-00311 | Include ball radius in calculation of PCS measured value | 
| Description | This parameter controls the inclusion of the touch probe ball radius in the PCS measured value (V.A.MEAS.PCS.VALUE.<Axis>), see also the chapter on Programming in [FCT-C4]). | 
| Parameter | meas_pcs_value_no_probe_radius | 
| Data type | BOOLEAN | 
| Data range | 0: The ball radius of the probe is included in the PCS measured value (default). * 1: The ball radius of the touch probe is not included in the PCS measured value. | 
| Dimension | ---- | 
| Default value | 0 | 
| Remarks | * The ball radius can only be considered if the probe is defined as a separate tool and is selected by the T/D word before the measurement travel. Additionally the ball radius must be entered as 'tool radius' in the tool data record. |