ID 51119
Other kinematic types are active than at interruption time. | ||||
Description | An attempt was made to execute an electrode extraction via the CNC cycle. The stored data for the retraction contains different kinematic transformation types than were active at interruption time. If this error is output, the kinematic types selected in the transferred program do not coincide with the stored kinematic types. | |||
Response | Class | 4 | Controlled stop for the axis group.´ | |
Solution | Class | 6 | Check and correct the program to select the kinematic transformations. | |
Parameter | %1: | Current value [-] | ||
Index of the incorrect kinematic transformation | ||||
%2: | Current value [-] | |||
Stored transformation type | ||||
%3: | Error value [-] | |||
Transformation type selected by the electrode cycle. | ||||
Error type | 1, Error message from NC program. | |||
|