ID 14409

Missing indication of feed rate from safety clearance to Z start position in pilot hole.

Description

The feed rate is not specified from the safety clearance to the Z start position in the pilot hole.

Response

Class

-

Error: Transition to error state. Complete reset of the NC channel necessary.

Solution

Class

-

Check parameter setting and specify the feed rate of the safety clearance to the Z start position in the pilot hole.

Error type

1, Error message from the NC program