Warning: HSC[SURFACE] MAX_ANGLE too big, value corrected.

Description

When the NC command #HSC[SURFACE …] is used, the keyword MAX_ANGLE can be used to define the maximum knee angle for transitions between two linear blocks.

The specified angle is too large and is corrected.

Response

Class

1

Warning is output and the parameter is corrected.

Solution

Class

1

Check and modify the NC program; correct the angle value.

Parameter

%1:

Error value [0.1 10^-3 mm or ø]

Specified angle value

%2:

Corrected value [0.1 10^-3 mm or ø]

Corrected angle value

Error type