Order of the actual speed filter in the case of feedhold on the conveyor axis (P-AXIS-00625)

P-AXIS-00625

Order of the velocity actual value filter in the case of feedhold on the conveyor axis

Description

This parameter defines the order (number of filtered values) of the velocity actual value filter if a feedhold is defined on the conveyor axis. The filter is off in the case of order 0. An FIR low-pass filter is used automatically.

Parameter

conv_sync.order_v_filter_dyn

Data type

UNS32

Data range

0 ≤ order_v_filter_dyn ≤ 1000

Axis types

T, R, S

Dimension

T: ----

R, S: ----

Default value

10

Drive types

----

Remarks

Available as of CNC Build V4.20.0