Order of the downstream velocity actual value filter in the case of feedhold on the conveyor axis (P-AXIS-00624)

P-AXIS-00624

Order of the downstream velocity actual value filter in the case of feedhold on the conveyor axis

Description

This parameter defines the order (number of filtered values) of the downstream velocity actual value filter of a feedhold is defined on the conveyor axis. The filter is off in the case of order 0. An average value filter is used automatically.

Parameter

conv_sync.order_post_v_filter

Data type

UNS32

Data range

0 ≤ order_post_v_filter ≤ 1000

Axis types

T, R, S

Dimension

T: ----

R, S: ----

Default value

6

Drive types

----

Remarks

Available as of CNC Build V4.20.0