Relative negative offset limit (P-AXIS-00137)

P-AXIS-00137

Relative negative offset limit in manual mode

Description

This parameter defines the relative negative offset limit. The relative positive offset limit is defined in P-AXIS-00138.

Parameter

handbetrieb.offsetgrenze_neg

Data type

SGN32

Data range

MIN(SGN32) ≤ offsetgrenze_neg ≤ 0

Axis types

T, R

Dimension

T: 0.1µm

R: 0.0001 °

Default value

-1000000

Drive types

----

Remarks

If the two relative offset limits

  • P-AXIS-00137 (offsetgrenze_neg) and
  • P-AXIS-00138 (offsetgrenze_pos)

are assigned the value 0, offset monitoring is disabled.