Brake premature time (P-AXIS-00375)
| P-AXIS-00375 | Brake premature time | |
| Description | This parameter defines the time which is required for the mechanical closing of the brake during control deactivation (e.g. via PLC by MC_Power 'Disable'). After this time expires, controller enabling is deselected. | |
| Parameter | antr.dse.brake_close_premature_time | |
| Data type | SGN32 | |
| Data range | 0 … MAX(SGN32) | |
| Axis types | T, R, S | |
| Dimension | T: µs | R,S: µs | 
| Default value | 0 | |
| Drive types | KUKA | |
| Remarks | Make sure that the brake premature time is not too short for a vertical axis, otherwise there is a danger that the axis drops. | |