Validation moment for command values (P-AXIS-00183)
| P-AXIS-00183 | Validation moment for command values | |
| Description | The parameter defines the validation moment for command values. | |
| Parameter | antr.sercos.times.t3 | |
| Data type | SGN16 | |
| Data range | MIN(SGN16) ≤ t3 ≤ MAX(SGN16) | |
| Axis types | T, R, S | |
| Dimension | T: μs | R,S: μs | 
| Default value | 0 | |
| Drive types | SERCOS | |
| Remarks | This parameter is not available under TwinCAT. | |