Maximum time for drive reset (P-AXIS-00484)
| P-AXIS-00484 | Maximum time for drive reset | |
| Description | By default an error message is output when the reset of a drive amplifier takes longer than 20 seconds. During this time the CNC axis can not be used. This parameter defines the time until output of the error message. Here a minimum value of 100000 µs is allowed. If P-AXIS-00484 is less than this minimum value warning, P-ERR-110562 is output and the parameter is set to the minimum value. | |
| Parameter | antr.reset_timeout | |
| Data type | UNS32 | |
| Data range | 100000 ≤ reset_timeout ≤ MAX(UNS32) | |
| Axis types | T, R, S | |
| Dimension | T: µs | R,S: µs | 
| Default value | 0 | |
| Drive types | ---- | |
| Remarks | 
 | |