Identifier for hardware specific parameter set (P-AXIS-00136)
P-AXIS-00136 | Identifier for hardware specific parameter set | |
Description | Each of the hardware-specific parameter sets has a logical identifier to identify which of the available hardware-specific parameter lists is valid. The active parameter set is selected by gear-specific parameter P-AXIS-00054 in gear-specific parameter set. The first parameter set is automatically assigned the identifier 1. | |
Parameter | lr_hw[i].nummer | |
Data type | SGN16 | |
Data range | 1, 2 (number of hardware-specific parameter sets, application-specific) | |
Axis types | T, R, S | |
Dimension | T: ---- | R, S: ---- |
Default value | 1 | |
Drive types | Simulation, Conventional, Terminal, Lightbus, Profidrive | |
Remarks | These entries are not adopted when the axis parameters list is updated. Updates only become effective when the controller is rebooted. |